21,717 research outputs found

    How to allocate scarce health resources without discriminating against people with disabilities

    Get PDF
    One widely used method for allocating health care resources involves the use of cost-effectiveness analysis (CEA) to rank treatments in terms of quality-adjusted life-years (QALYs) gained. CEA has been criticized for discriminating against people with disabilities by valuing their lives less than those of non-disabled people. Avoiding discrimination seems to lead to the ’QALY trap’: we cannot value saving lives equally and still value raising quality of life. This paper reviews existing responses to the QALY trap and argues that all are problematic. Instead, we argue that adopting a moderate form of prioritarianism avoids the QALY trap and disability discrimination

    Non-linear autopilot design using the philosophy of variable transient response

    Get PDF
    The novel non-linear controller design methodology of Variable Transient Response (VTR) is presented in this research. The performance of VTR is compared to that of successful non-linear controller designs (such as Robust Inverse Dynamics Estimation and a traditional autopilot design) by application to a non-linear missile model. The simulated results of this application demonstrate that the inclusion of VTR into the RIDE design results in a 50% improvement in response time and 100% improvement in settling time whilst achieving stable and accurate tracking of a command input. Analysis demonstrates that VTR dynamically alters the system's damping, resulting in a non-linear response. The system stability is analysed during actuator saturation using non-linear stability criteria. The results of this analysis show that the inclusion of VTR into the RIDE design does not compromise non-linear system stability

    Process for application of powder particles to filamentary materials

    Get PDF
    This invention is a process for the uniform application of polymer powder particles to a filamentary material in a continuous manner to form a uniform composite prepreg material. A tow of the filamentary material is fed under carefully controlled tension into a spreading unit, where it is spread pneumatically into an even band. The spread filamentary tow is then coated with polymer particles from a fluidized bed, after which the coated filamentary tow is fused before take-up on a package for subsequent utilization. This process produces a composite prepreg uniformly without imposing severe stress on the filamentary material, and without requiring long, high temperature residence times for the polymer

    Photovoltaic system criteria documents. Volume 1: Guidelines for evaluating the management and operations planning of photovoltaic applications

    Get PDF
    Guidelines are provided to the Field Centers for organization, scheduling, project and cost control, and performance in the areas of project management and operations planning for Photovoltaics Test and Applications. These guidelines may be used in organizing a T and A Project Team for system design/test, site construction and operation, and as the basis for evaluating T and A proposals. The attributes are described for project management and operations planning to be used by the Field Centers. Specifically, all project management and operational issues affecting costs, schedules and performance of photovoltaic systems are addressed. Photovoltaic tests and applications include residential, intermediate load center, central station, and stand-alone systems. The sub-categories of system maturity considered are: Initial System Evaluation Experiments (ISEE); System Readiness Experiments (SRE); and Commercial Readiness Demonstration Projects (CRDP)

    Bacterial cross-contamination between the dental clinic and laboratory during prosthetic treatment

    Get PDF
    Prosthetic treatment involves various stages in construction. This may result in cross-contamination between the dental clinic and laboratory. According to results obtained from the study, recommendations were made so as to reduce as much as possible cross-contamination, making a safer environment for the dental team and patient.peer-reviewe

    Bacterial atmospheric contamination during routine dental activity

    Get PDF
    Routine dental procedures cause atmospheric bacterial contamination in the dental clinic and laboratory. This environmental hazard, quantified by the Air Microbial Index, was shown in our study to be directly related to aerosol creating instruments and ventilation.peer-reviewe

    Photovoltaic system criteria documents. Volume 3: Environmental issues and evaluation criteria for photovoltaic applications

    Get PDF
    The environmental issues and evaluation criteria relating to the suitability of sites proposed for photovoltaic (PV) system deployment are identified. The important issues are defined, briefly discussed and then developed into evaluation criteria. System designers are provided with information on the environmental sensitivity of PV systems in realistic applications, background material which indicates the applicability of the siting issues identified, and evaluation criteria are defined to facilitate the selection of sites that maximize PV system operation
    corecore